Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2007 Vol. 3
p
 
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 3
Nanotech 2007 Vol. 3
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 3
 
Chapter 4: Micro and Nano Fluidics
 

On-site Screening of Avian Influenza Virus (AIV) by Polystyrene Microfluidic Chip Immunoassay

Authors:Y. Zhao, M. Zou, Q. Xue and P. Zhou
Affilation:The Chinese Academy of Inspection and Quarantine, CN
Pages:399 - 402
Keywords:polystyrene microfluidic chip, micro-channels, AIV
Abstract:AIV Ag of A type with viral nucleoprotein (NP), which covers all AIV subtypes, including high-pathogenic AIV was determined by polystyrene microfluidic chip ELISA method. In micro-channels of chip instead of conventional 96-well microtiter plates, a double-antibody sandwich ELISA (DAS-ELISA) was developed, in which rabbit Ab, mouse nuclear protein (NP) mAb and horseradish peroxidase-conjugated goat anti-mouse immunoglobin were used as coating, primary and secondary antibodies, respectively. Recombine Ag of AIV was prepared as positive control to ensure the on-site test safety. With TMB as substrate, AIV Ag could distinctly be judged by comparing colors of sample detection windows with that of the negative control in micro-channels, a preliminary result was obtained in accordance with conventional ELISA while total analytical time were within 1 h. The on-chip DAS-ELISA was well applicable to rapid and real-time screening of AIV. The sensitivity could be further improved by optimization experiments.
On-site Screening of Avian Influenza Virus (AIV) by Polystyrene Microfluidic Chip ImmunoassayView paper
ISBN:1-4200-6184-4
Pages:732
Hardcopy:$199.99
 
Order:Mail/Fax Form
Special:3 CD Set — 15% off with Free Shipping
Up
Upcoming Events
Nanotech 2009
Cleantech 2009
BioNano 2009
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact