Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2007 Vol. 2
p
 
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 2
Nanotech 2007 Vol. 2
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 2
 
Chapter 6: Biosensors
 

Quantitative measurements of the strength of adhesion of human neutrophils to a substratum in a microfludic device: A novel inflammation diagnostic tool

Authors:E. Gutierrez and A. Groisman
Affilation:University of California, San Diego, US
Pages:527 - 530
Keywords:neutrophils, shear stress, microfluidic, inflammation, fMLP, fibrinogen
Abstract:We describe a quantitative assay of the strength of adhesion of activated and non-activated human neutrophils to a substratum, which is carried out in a custom-made microfluidic device. The strength of adhesion is quantified by the fraction of cells remaining adherent (ACF) after a given time of exposure to shear stress in a test microchannel. The microfluidic device is made of two layers of polydimethylsiloxane (PDMS) with integrated membrane valves. This construction allows concurrent testing of two different populations of cells, as well as setting well-defined times of exposure of cells to stress and of their incubation prior to the exposure. The test microchannels have a tapered profile, exposing cells to nearly an order-of-magnitude range of shear stress. ACF is measured periodically by video-microscopy scans of the device, with up to 60,000 individual cells identified within a 90 sec scan. The high throughput of the scans allows reliable quantitative assessment of the ACF. Adhesion of untreated neutrophils and neutrophils activated with fMLP (formyl-Met-Leu-Phe) was tested concurrently in a series of experiments with a fibrinogen-coated glass substratum. At optimized testing conditions, the ACF of activated cells was consistently found to be three times higher than that of non-activated cells. The proposed device and assay could be used to assess the state of activation of neutrophils in human blood with a potential application to diagnostics of inflammation.
ISBN:1-4200-6183-6
Pages:838
Hardcopy:$199.99
 
Order:Mail/Fax Form
Special:3 CD Set — 15% off with Free Shipping
Up
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact