Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2007 Vol. 2
p
 
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 2
Nanotech 2007 Vol. 2
Technical Proceedings of the 2007 NSTI Nanotechnology Conference and Trade Show, Volume 2
 
Chapter 6: Biosensors
 

A Non-Oxidative Sensor Based on a Self-Doped Polyaniline/Carbon Nanotube Composite for Highly Sensitive and Selective Detection of the Neurotransmitter Dopamine

Authors:S.R. Ali, Y. Ma, R.R. Parajuli, Y. Balogan, W.Y-C. Lai and H. He
Affilation:Rutgers University, US
Pages:523 - 526
Keywords:polyaniline, boronic acid, carbon nanotubes, voltammetry, detection of dopamine, Parkinson's disease, ascorbic acid, ascorbate oxidase
Abstract:The ability to measure the concentration of dopamine sensitively and selectively could potentially be used for molecular diagnosis of Parkinson’s disease. The ability to monitor its concentration in-vivo also benefits in design therapies and evaluating the therapeutic efficacy. However, to design a biosensor capable of measuring dopamine at its site of action is challenging. First of all, the concentration of dopamine in the extracelluar fluid of the caudate nucleus in brains is extremely low (tens of nanomoles for normal person, several nanomoles for parkinson’s patient). The challenge is being magnified for in-vivo measurement because the concentration of ascorbic acid, the main detection interference, is 4 to 5 magnitude higher than dopamine. Current detection techniques, including the enzymatic approaches, all suffered from a common problem, i.e. the oxidation products of dopamine could react with ascorbic acid in the sample, which results in severe interference of the detection. Most of the current detection techniques for in-vivo detection of dopamine exploit the neurotransmitter’s ease of oxidation. However, the oxidative approaches including enzymatic oxidation approaches, suffer from a common problem. The oxidation products of dopamine can react with the electrode surface, which causes electrode fouling. The products can also react with ascorbic acid in samples and regenerate dopamine, which severely limits the potential for accurate detection. In this paper, we report a non-oxidative approach to electrochemically detect dopamine with high sensitivity and selectivity (Figure 1). This approach takes advantage of the high performance of our newly developed poly(anilineboronic acid)/carbon nanotube composite and the excellent permselectivity of the ion-exchange polymer Nafion. The binding of dopamine to the boronic acid groups of the polymer with large affinity affects the electrochemical properties of the polyaniline backbone, which act as the transduction mechanism of this non-oxidative dopamine sensor. The unique reduction capability and high conductivity of single-stranded DNA functionalized single-walled carbon nanotubes greatly improved the electrochemical activity of the polymer in physiologically buffers, and the large surface area of the carbon nanotubes largely increased the density of the boronic acid receptors. The high sensitivity and selectivity of the sensor (Figure 2, 3) show excellent promise toward molecular diagnosis of Parkinson's disease.
ISBN:1-4200-6183-6
Pages:838
Hardcopy:$199.99
 
Order:Mail/Fax Form
Special:3 CD Set — 15% off with Free Shipping
Up
Upcoming Events
Nanotech 2009
Cleantech 2009
BioNano 2009
TechConnect Summit
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact