Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2006 Vol. 2
p
 
Technical Proceedings of the 2006 NSTI Nanotechnology Conference and Trade Show, Volume 2
Nanotech 2006 Vol. 2
Technical Proceedings of the 2006 NSTI Nanotechnology Conference and Trade Show, Volume 2
 
Chapter 3: Bio Sensors and Diagnostics
 

A Novel, Low Power Biosensor for Real Time Monitoring of Creatinine and Urea in Peritoneal Dialysis

Authors:B. Premanode and C. Toumazou
Affilation:Institute of Biomedical Engineering, UK
Pages:221 - 224
Keywords:biosensors, ISFET, Weak Inversion, Dialysis
Abstract:Novel biosensors, based on immobilized creatininase, creatinase and urease are developed, using ISFETs with weak inversion at pH 6-8 and 37.0oC. The ISFETs with circuitry, demonstrate a linear relationship of urea and creatinine at the range of 0-200 mM and 0-20 mM, respectively. Preliminary results show that biosensors operating in weak inversion mode can eliminate many of the disadvantages of ISFETs operating in the strong inversion region, providing a wide dynamic range output in nanoAmp. Such characteristics fit the analytical requirements for improving real-time monitoring in Peritoneal Dialysis (PD). Further work covers stability of ISFET sensors biased with CMOS circuits in the weak inversion mode working in the room temperature of 15 to 40°C.