Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2004 Vol. 1
p
 
Technical Proceedings of the 2004 NSTI Nanotechnology Conference and Trade Show, Volume 1
Nanotech 2004 Vol. 1
Technical Proceedings of the 2004 NSTI Nanotechnology Conference and Trade Show, Volume 1
 
Chapter 7: Micro Fluidics and Nanoscale Transport
 

In-Plane Micropump: Design Optimization

Authors:J. Sin, W.H. Lee and H.E. Stephanou
Affilation:RPI, US
Pages:271 - 274
Keywords:micropump, electrothermal, modeling, power, optimization
Abstract:This paper presents the fabrication, analysis and optimization of a novel monolithically fabricated diaphragm micropump, referred to as an in-plane micropump. Compared to previous technology, the micropump in this paper is fabricated to have all necessary components in a single silicon layer. The actuation principle is electrothermal expansion of a silicon V-beam, and its expansion is amplified through a lever structure to create a greater diaphragm stroke. Either a check valve or a diffuser is incorporated with a diaphragm to direct fluid flow. The Deep RIE (Reactive Ion Etching) process is used to fabricate the pump structure on a SOI (Silicon On Insulator) wafer, and the electromechanical property of the pump structure is characterized to estimate the pump's performance. Considering that minimization of energy consumption is one of the critical design objectives in micropumps, the design parameters of the pump structure are optimized for minimal driving power.
ISBN:0-9728422-7-6
Pages:521
Hardcopy:$150.00
 