Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2003 Vol. 1
p
 
Technical Proceedings of the 2003 Nanotechnology Conference and Trade Show, Volume 1
Nanotech 2003 Vol. 1
Technical Proceedings of the 2003 Nanotechnology Conference and Trade Show, Volume 1
 
Chapter 11: MEMS Design and Application
 

High Resolution Silicon Accelerometer Using Eutectic Bonding

Authors:Y. Kwang, J.C. Yeon, Y.H. Kim, S.W. Rhee and S.H. Oh
Affilation:Seoul National University, KR
Pages:396 - 399
Keywords:microaccelerometer, differential capacitive, Eutectic bonding
Abstract:High precision micro-accelerometers are used in many applications such as automotives, aviations and aerospace navigation systems. In this paper, a lateral capacitive micro-accelerometer with _g level resolution has been designed and fabricated using simple micromachining process. Large sensing area and large proof mass are important in the design of high precision accelerometer.[1,2] To satisfy these requirements, the differential capacitive comb type is adopted for the sensing part, and the bulk-micromachining is used to define the micro structure. A glass wafer is used to make electrical isolation between the proof mass and electrode. Anchor and gold electrode is pre-defined on the silicon wafer and glass wafer respectively, and bonded each other. Eutectic bonding is used for bonding process of silicon and glass. The role of gold film is not only an adhesion layer but also an electrode layer. The stiction problem which can occur due to wet release process can be removed by using this process. The accelerometer has a 50_m-thick proof mass, 870_m 1027_m in size with 3_m sensing gap defined by deep RIE process. Spring has 3~5_m thickness and 200~300_m length. Proof mass weighs 15.84_gram, and natural frequency is 13.78KHz. This accelerometer is designed to control spring stiffness and force balancing loop to improve resolution.
High Resolution Silicon Accelerometer Using Eutectic BondingView paper
ISBN:0-9728422-0-9
Pages:560
Hardcopy:$125.00
Special:3 CD Set — 15% off with Free Shipping
Up
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact