MSM 2000
MSM 2000
Technical Proceedings of the 2000 International Conference on Modeling and Simulation of Microsystems

Equivalent Circuits, Behavioral and Multi-Level Simulation Chapter 5

Integration of a Permeable Layer into Micro Coil Modelling and First Steps of Automatic Optimization

Authors: S. Rehfuß, D. Peters and R. Laur

Affilation: University of Bremen (ITEM), Germany

Pages: 197 - 200

Keywords: micro coil, rectangular, modelling, permeable layer, optimization

Abstract:
Rectangular micro coils which are used in a wide range of applications (e.g. medical or automotive area) are the main components of appropriate wireless transmission systems for frequencies up to 20 MHz. As shown in previous works the self inductance of micro coils has to be maximezed to achieve a higher working distance. One possible solution is the usage of a permeable layer underneath the micro coil. The modification of an existing model by use of the magentic image method and first low frequency results are presented. Another wa to increase the performance of micr coil based systems is the optimization of all coil parameters. Algorithms that best fit the demands of automatic model based design optimizations are the so called direct search strategies. Such strategies and first results of an optimization process are presented.


ISBN: 0-9666135-7-0
Pages: 741

2015 & Newer Proceedings

Nanotech Conference Proceedings are now published in the TechConnect Briefs

NSTI Online Community