Nano Science and Technology Institute - NSTI  
Nano Science and Technology Institute   Home | Subscribe | Site Map  
  ABOUT | COURSES | EVENTS | PUBLICATIONS | LEADERSHIP | OUTREACH | NEWS | PRESS | JOBS | Nanotechnology Solutions
px
px fade_top
Publications
Nanotech 2008 CDROM
Nanotech 2007 CDROM
Nanotech 2006 CDROM
Nanotech 2005 CDROM
Nanotech 2004 CDROM
3 CDROM Special Offer
Nanotech 2008 Vol. 1
Nanotech 2008 Vol. 2
Nanotech 2008 Vol. 3
Nanotech 2007 Vol. 1
Nanotech 2007 Vol. 2
Nanotech 2007 Vol. 3
Nanotech 2007 Vol. 4
Nanotech 2006 Vol. 1
Nanotech 2006 Vol. 2
Nanotech 2006 Vol. 3
Nanotech 2005 Vol. 1
Nanotech 2005 Vol. 2
Nanotech 2005 Vol. 3
WCM 2005
Nanotech 2004 Vol. 1
Nanotech 2004 Vol. 2
Nanotech 2004 Vol. 3
Nanotech 2003 Vol. 1
Nanotech 2003 Vol. 2
Nanotech 2003 Vol. 3
Nanotech 2002 Vol. 1
Nanotech 2002 Vol. 2
Nanotech 2001 Vol. 1
Nanotech 2001 Vol. 2
MSM 2000
MSM 99
MSM 98
Index of Authors
Index of Keywords
Index of Affiliations
Library Request Form
Shopping Cart
Order Form
 
Publications Publications
Nanotech 2002 Vol. 2
p
 
Technical Proceedings of the 2002 International Conference on Computational Nanoscience and Nanotechnology
Nanotech 2002 Vol. 2
Technical Proceedings of the 2002 International Conference on Computational Nanoscience and Nanotechnology
 
Chapter 14: Process Modeling
 

Characterization of Ion Implantation in Si Using Infrared Spectroscopy with a Lock-In common-Mode-Rejection Demodulation

Authors:F. Rábag, A. Mandelis and A. Salnik
Affilation:University of Toronto, Canada
Pages:376 - 379
Keywords:semiconductors, ion implantation, photothermal radiometry
Abstract:B+, P+, and As+ ion-implanted Si wafers in the implantation dose range 1x1011 - 1x1013 ions/cm2 were characterized using Photothermal Radiometry (PTR). A comparison between the conventional frequency scan and a new technique called Common-Mode-Rejection Demodulation (CMRD) was done. It was found that the CMRD technique can significantly enhance the resolution of PTR response curves from P+ ion implanted wafers in cases where conventional square wave frequency scans were totally or partially unable to resolve the dose. The dose resolution improvements afforded by the CMRD technique may be important toward better control of the ion implantation process in electronic devices, in a dose range which has traditionally been difficult to monitor optically owing to the effects induced by the early stages of the amorphization process in the implanted layer.
Characterization of Ion Implantation in Si Using Infrared Spectroscopy with a Lock-In common-Mode-Rejection DemodulationView paper
ISBN:0-9708275-6-3
Pages:504
Hardcopy:$100.00
Special:3 CD Set — 15% off with Free Shipping
Up
nanoPRwire™
nanoPRwire
News Headlines
nano World news
 
 
 
 
px
© Nano Science and Technology Institute     About NSTI | Terms of Use | Privacy Policy | Contact