2008 NSTI Nanotechnology Conference and Trade Show - Nanotech 2008 - 11th Annual

Partnering Events:

TechConnect Summit
Clean Technology 2008

Design and Simulations of a Microfluidic Pump with Multiple Vibrating Membranes

K. Koombua, R.M. Pidaparti, P.W. Longest, G.M. Atkinson
Virginia Commonwealth University, US

Keywords:
microfluidics, design, simulation, micropump, valveless

Abstract:
A novel design of a micropump with multiple vibrating membranes has been developed in this study. The micropump consists of three nozzle/diffuser elements with vibrating membranes, which are used to create pressure difference in the pump chamber. The fluidic characteristics of this micropump were analyzed using FLUENT, the computational fluid dynamics (CFD) solver based on the finite volume method. The dynamic mesh algorithm was employed to study transient responses of fluid velocity, pressure distributions, and flow rate during the operating cycle of the micropump. The design simulation results showed that the movement of wall membranes combined with the rectification behavior of three nozzle/diffuser elements can minimize back flow and improve net flow in one direction.